Product Description
pH/Conductivity Meter
In some applications there may be a need to measure different parameters of a solution. The same can be fulfilled by using a single instrument with different electrodes for the respective parameter. A single instrument can measure simultaneously different combinations such as pH / Conductivity, pH/ Ion concentration, pH /Dissolved oxygen, Conductivity/Dissolved oxygen along with temperature. These instruments find usage in environmental protection, water quality checking, biological agriculture, aqua culture, scientific research and studies, etc.
Features :
- 1. pH , mV, Conductivity, Resistivity, TDS, Salinity, Temperature modes.
- 2. Automatic or Manual temperature Compensation.
- 3. 3 point pH calibration.
- 4. Buffers selectable from 1.68pH, 4.00pH, 4.01pH, 6.86pH, 7.00pH, 9.18pH, 9.20pH. 10.01pH and 12.45pH
- 5. Automatic buffer recognition.
- 6. 1 point conductivity calibration for the entire range.
- 7. Bi directional RS232 interface. Baud rate selectable from 1200,2400,4800 and 9600.
- 8. Single and continuous print out of measuring parameters.
- 9. Multiple Printout types. Combinations selectable from Sr. No., pH, mV, conductivity, TDS, Salinity, Date, time and temperature.
- 10. Real Time Clock.
- 11. Calibration report as per GLP requirements.
- 12. Electrode Slope and mV offset display.
- 13. LCD display with Backlight.
- 14. Memory storage of 100 measurements.
- 15. Data logging facility up to 500 results. Data logging interval selectable from 5S, 10S, 20S, 30S, 1M, 2M and 5M.
- 16. Temperature calibration with respect to solution of known temperature.
Specifications :
- pH Range: 0-14pH
- mV Range: +/-1999.9mV
- Conductivity Range: 0~200mS/cm spread into 5 ranges
- 0.00~20.00S/cm, 20.0~200.0S/cm,
- 200~2000 S/cm
- 2.00~20.00mS/cm, 20.0~200.0 mS/cm,
- Resistivity Range : 0~100M;cm
- TDS Range : 0~100ppt(g/L)
- Salinity Range : 0~100ppt
- Temperature Range : -10.0~110. C
- pH Accuracy : +/-0.02pH
- mV Accuracy : +/-1mV
- Conductivity Accuracy : +/-1% FS
- Temperature Accuracy : +/-1% FS
- ATC pH : 0~100 C
- ATC Conductivity : 0~50 C
- pH Electrode : pH combination electrode-EpHG03
- Temperature Electrode : Temperature sensor electrode-ETS01
- Conductivity Electrode : ECNG01
-
- Power : 9V/ 500 mA External adaptor
- Operating Temperature : 15~45oC
- Meter Dimensions (mm) : 165 (L) x 190 (D) x 60 (H)
- Meter Weight : 700 g
-
- Optional Accessories : Magnetic Stirrer MS-01,
- Battery backup unit BBEC-01
- Calibration Standards